The process of generating a rise-time or fall-time pulse of a pulse signal.  The transition can be either be in a positive direction (Risetime) or a negative direction (Fall time).

Required Parameters

  • Transition – {Rise, Fall}
  • Vpp – Requested Volts Peak to Peak

Optional Parameters

  • TransitionTime – in Seconds (0 s indicates as fast as possible)
  • Type -{10To90, 20To80}
  • Period – in Seconds
  • Width – in Seconds
  • Offset – in Volts
  • Impedance – Ohms

Measured Value & Uncertainty

  • Time – in Seconds