A test process that measures the ratio between the AC ripple & noise in RMS voltage measured on a DC signal then divided by the DC voltage level creating a ratio between the two voltages.
Required Parameters
- Volts – DC Voltage
Optional Parameters
- Impedance – Input impedance of the measuring device. Expected output impedance of a source.
- Bandwidth – High pass filter frequency limit
- UUT.Output – Output Name of the UUT Connecting Point
Output Value & Uncertainty
- to1 -AC Volts / DC Volts
- % -AC Volts / DC Volts * 100